Use este identificador para citar ou linkar para este item: http://bdex.eb.mil.br/jspui/handle/123456789/5616
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.advisorNeves, Angela Nogueira-
dc.contributor.authorIahnke, Vinícius Jacondino-
dc.date.accessioned2020-02-10T18:14:56Z-
dc.date.available2020-02-10T18:14:56Z-
dc.date.issued2019-
dc.identifier.urihttp://bdex.eb.mil.br/jspui/handle/123456789/5616-
dc.descriptionCorrelação e concordância entre o volume de oxigênio máximo e o kasari fit indexpt_BR
dc.description.abstractINTRODUÇÃO: o Kasari Fit Index (KFI) é uma avaliação do condicionamento físico aeróbico, baseada no produto da frequência, intensidade, duração autorreportados do exercício. OBJE-TIVO: verificar a correlação e concordância do KFI com o VO2max, obtido através do teste de Cooper 12 min e do protocolo em rampa. MÉTODOS: a amostra foi composta por 24 alunos do curso de Instrutores de Educação Física (26,5 ± 2,39 anos) e 35 membros da família militar (45,28 ± 10,79 anos). Com os dados de VO2max obtidos com o teste de Cooper e o KFI dos participantes do Curso de Instrutores da EsEFEx, assim como VO2max obtidos no protocolo Rampa e o KFI dos membros da família militar, verificamos a correlação dos pares de variáveis (KFI x VO2maxCo-oper e KFI x VO2maxRampa) através do teste de correlação de Pearson. O coeficiente de concordância (ρc) e a análise gráfica de Bland e Altman, foram utilizados para avaliação da concordância. O software SPSS 15 e MedCalc foram usados. RESULTADOS: O teste de correlação de Pearson indicou haver correlação e moderada entre KFI x VO2maxCooper (r = 0, 45; p = 0,02) e correlação não significante entre KFI x VO2maxRampa (r = 0,11, p = 0,55). Quanto à concordancia entre Kasari x VO2maxCooper, foi encontrado um coeficiente de concordancia (ρc) pobre (ρc= 0,13; sendo Cb = 0,31), enquanto para KFI x VO2maxRampa o mesmo foi deprezível (ρc= 0,04; sendo Cb = 0,41). No gráfico Bland-Altman, para os dois pares de dados testados, verificou-se viés de diferença consi-derável, o que constitui margens amplas de sub e superestimação do VO2max pelo KFI, sendo que apenas para KFI x VO2maxRampa 5,71% dos dados estavam fora da margem indicativa de boa con-cordância. CONCLUSÃO: a utilização do Kasari Fit Index deve-se restringir à descrição da intensidade, duração e frequência do exercício praticado. ______________________________________________________________________________pt_BR
dc.description.abstractABSTRACT INTRODUCTION: The Kasari Fit Index (KFI) is an assessment of aerobic fitness based on the product of self-reported exercise frequency, intensity, duration. OBJECTIVE: To verify the cor-relation and agreement between KFI and VO2max, obtained through the Cooper 12 min test and the ramp protocol. METHODS: The sample consisted of 24 Physical Education Instructor stu-dents (26.5 ± 2.39 years) and 35 military family members (45.28 ± 10.79 years). With the VO2max data obtained with the Cooper test and the KFI of the EsEFEx Instructor Course participants, as well as the VO2max obtained from the Ramp protocol and the KFI of the military family members, we verified the correlation of the pairs of variables (KFI x VO2maxCooper and KFI x VO2maxRampa) by Pearson's correlation test. Agreement coefficient (ρc) and Bland and Altman graphical analysis were used to evaluate agreement. The software SPSS 15 and MedCalc were used. RESULTS: Pearson's correlation test indicated a moderate correlation between KFI x VO2maxCooper (r=0.45, p = 0.02) and non-significant correlation between KFI x VO2maxCampa (r = 0.11, p = 0.55). Concerning the agreement between Kasari x VO2maxCooper, a poor agree-ment coefficient (ρc) was found (ρc = 0.13; Cb = 0.31), while for KFI x VO2maxRampa it was negligible (ρc = 0.04; Cb = 0.41). In the Bland-Altman graph, for the two data pairs tested, there was a considerable difference bias, which constitutes wide margins of VO2max underestimation and overestimation by KFI, and only for KFI x VO2maxRamp 5.71%. data were outside the in-dicative margin of good agreement. CONCLUSION: The use of the Kasari Fit Index should be restricted to describing the intensity, duration and frequency of the exercise performed.pt_BR
dc.language.isopt_BRpt_BR
dc.subjectAptidão físicapt_BR
dc.subjectCondicionamento físico aeróbiopt_BR
dc.subjectinformações autorreportadaspt_BR
dc.titleCorrelação e concordância entre o volume de oxigênio máximo e o kasari fit indexpt_BR
dc.typeArtigopt_BR
dc.rights.licenseÉ permitida a reprodução de parte do conteúdo da obra, desde que seja, obrigatoriamente, citada a fonte. É proibida a reprodução para fins comerciais, bem como qualquer alteração no conteúdo da obra. Autorizada a disponibilização na BDEx.pt_BR
Aparece nas coleções:DECEX:CCFEX: ESEFEX

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Iahnke.pdf2,21 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.