Use este identificador para citar ou linkar para este item:
http://bdex.eb.mil.br/jspui/handle/123456789/13735
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.advisor | Mello, Danielli Braga de | - |
dc.contributor.author | Feitosa, Thiago Rodrigues | - |
dc.date.accessioned | 2024-07-05T13:19:14Z | - |
dc.date.available | 2024-07-05T13:19:14Z | - |
dc.date.issued | 2023 | - |
dc.identifier.uri | http://bdex.eb.mil.br/jspui/handle/123456789/13735 | - |
dc.description | Trabalho de Conclusão de Curso apresentado como requisito parcial para conclusão da graduação em Educação Física na Escola de Educação Física do Exército. | pt_BR |
dc.description.abstract | INTRODUÇÃO: A termografia infravermelha (TIV) tem se mostrado eficaz na avaliação das respostas termorreguladoras da pele e do corpo durante o exercício físico. O pé possui elevada importância para termorregulação do corpo, assim um coturno adequado pode contribuir significativamente para a saúde e o desempenho dos atletas táticos. O objetivo do estudo foi analisar a temperatura dos pés utilizando o coturno de combate distribuído pela cadeia de suprimento do Exército Brasileiro (EB) e tênis de corrida MÉTODOS: Participaram do estudo 8 atletas táticos (27,13 ± 2,1 anos). Fizeram teste ergométrico com protocolo de rampa, em laboratório com ambiente termoneutro em duas ocasiões: com novo fardamento do EB (camisa e calça) e coturno de combate preto da cadeia de suprimento com meia ou com short e tênis de corrida Olympikus® Corre 3. A TIV da planta dos pés foi coletada pré e pós-teste com câmera infravermelha Flir E76®. As Regiões de Interesse (ROIs) foram: Hálux (HA), 2 ao 5 dedo (DD), Metatarso 1 (M1), Metatarso 2 a 4 (M4), Metatarso 5 (M5), Arco medial (AM), Arco lateral (AL), Calcanhar interno (CI) e Calcanhar externo (CE) no pé direito (D) e esquerdo (E). Foi utilizado o teste estatístico Wilcoxon para comparar os momentos pré e pós teste e o teste estatístico Mann Whitney para comparar a diferença entre os dois grupos. RESULTADOS: Foi observado aumento significativo de temperatura (pré x pós) com os dois calçados em todas as ROIs. Quando comparado a variação de temperatura ocorrida com coturno ou tênis entre os momentos pré x pós apenas na ROI CI D foi observado diferença significativa. CONCLUSÃO: Portanto, pode-se concluir que o comportamento termorregulatório do pé foi similar com coturno de combate ou tênis de corrida._____________________________________INTRODUCTION: Infrared thermography (TIV) has been shown to be effective in evaluating the thermoregulatory responses of the skin and body during physical exercise. The foot is highly important for the body's thermoregulation, so adequate combat boots can significantly contribute to the health and performance of tactical tactics. The objective of the study was to analyze foot temperature using combat boots distributed by the Brazilian Army (EB) supply chain and running shoes METHODS: 8 tactical athletes (27.13 ± 2.1 years) participated in the study. They carried out an ergometric test with a ramp protocol, in a laboratory with a thermoneutral environment, on two occasions: with new EB uniforms (shirt and pants) and black combat boots from the supply chain with socks or with shorts and Olympikus® Corre 3 running shoes. The TIV of the soles of the feet was collected pre- and post-test with a Flir E76® infrared camera. The Regions of Interest (ROIs) were Hallux (HA), 2nd to 5th toes (DD), Metatarsus 1 (M1), Metatarsus 2 to 4 (M4), Metatarsus 5 (M5), Medial arch (AM), Lateral arch (AL), Inner heel (CI) and Outer heel (CE) on the right (R) and left (E) foot. The Wilcoxon statistical test was used to compare the pre and post test moments and the Mann-Whitney statistical test was used to compare the difference between the two groups. RESULTS: A significant increase in temperature (pre x post) was observed with both shoes in all ROIs. When compared to the temperature variation occurred with combat boots or sneakers between the pre x post moments, only in the CI D ROI was a significant difference observed. CONCLUSION: Therefore, it can be concluded that the thermoregulatory behavior of the foot was like combat boots or running shoes. | pt_BR |
dc.language.iso | pt_BR | pt_BR |
dc.subject | Atleta tático | pt_BR |
dc.subject | Regulação da temperatura corporal | pt_BR |
dc.subject | Vestimenta | pt_BR |
dc.title | Análise da temperatura do pé de militares do Exército Brasileiro usando dois calçados diferentes : estudo preliminar | pt_BR |
dc.type | Monografia | pt_BR |
dc.rights.license | É permitida a reprodução do conteúdo da obra desde que seja, obrigatoriamente, citada a fonte. É proibida a reprodução para fins comerciais, bem como qualquer alteração no conteúdo da obra. Autorizada a disponibilização na BDEx pelo autor. | pt_BR |
Aparece nas coleções: | DECEX:CCFEX: ESEFEX |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
RODRIGUES_TCC.pdf | 485,44 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.